Columns

The ratio of the effective length of a column to the least radius of gyration of its cross section is called the slenderness ratio (sometimes expressed with the Greek letter lambda, λ). This ratio affords a means of classifying columns. Slenderness ratio is important for design considerations. All the following are approximate values used for convenience.

  • A short steel column is one whose slenderness ratio does not exceed 50; an intermediate length steel column has a slenderness ratio ranging from about 50 to 200, and are dominated by the strength limit of the material, while a long steel column may be assumed to have a slenderness ratio greater than 200.
  • A short concrete column is one having a ratio of unsupported length to least dimension of the cross section not greater than 10. If the ratio is greater than 10, it is a long column (sometimes referred to as a slender column).
  • Timber columns may be classified as short columns if the ratio of the length to least dimension of the cross section is equal to or less than 10. The dividing line between intermediate and long timber columns cannot be readily evaluated. One way of defining the lower limit of long timber columns would be to set it as the smallest value of the ratio of length to least cross sectional area that would just exceed a certain constant K of the material. Since K depends on the modulus of elasticity and the allowable compressive stress parallel to the grain, it can be seen that this arbitrary limit would vary with the species of the timber. The value of K is given in most structural handbooks.

If the load on a column is applied through the center of gravity of its cross section, it is called an axial load. A load at any other point in the cross section is known as an eccentric load. A short column under the action of an axial load will fail by direct compression before it buckles, but a long column loaded in the same manner will fail by buckling (bending), the buckling effect being so large that the effect of the direct load may be neglected. The intermediate-length column will fail by a combination of direct compressive stress and bending.

In 1757, mathematician Leonhard Euler derived a formula that gives the maximum axial load that a long, slender, ideal column can carry without buckling. An ideal column is one that is perfectly straight, homogeneous, and free from initial stress. The maximum load, sometimes called the critical load, causes the column to be in a state of unstable equilibrium; that is, the introduction of the slightest lateral force will cause the column to fail by buckling. The formula derived by Euler for columns with no consideration for lateral forces is given below. However, if lateral forces are taken into consideration the value of critical load remains approximately the same.

where

= maximum or critical force (vertical load on column),
= modulus of elasticity,
= area moment of inertia,
= unsupported length of column,
= column effective length factor, whose value depends on the conditions of end support of the column, as follows.
For both ends pinned (hinged, free to rotate), = 1.0.
For both ends fixed, = 0.50.
For one end fixed and the other end pinned, = 0.699....
For one end fixed and the other end free to move laterally, = 2.0.
is the effective length of the column.

Examination of this formula reveals the following interesting facts with regard to the load-bearing ability of slender columns.

  1. Elasticity and not compressive strength of the materials of the column determines the critical load.
  2. The critical load is directly proportional to the second moment of area of the cross section.
  3. The boundary conditions have a considerable effect on the critical load of slender columns. The boundary conditions determine the mode of bending and the distance between inflection points on the deflected column. The closer together the inflection points are, the higher the resulting capacity of the column.

The strength of a column may therefore be increased by distributing the material so as to increase the moment of inertia. This can be done without increasing the weight of the column by distributing the material as far from the principal axis of the cross section as possible, while keeping the material thick enough to prevent local buckling. This bears out the well-known fact that a tubular section is much more efficient than a solid section for column service.

Another bit of information that may be gleaned from this equation is the effect of length on critical load. For a given size column, doubling the unsupported length quarters the allowable load. The restraint offered by the end connections of a column also affects the critical load. If the connections are perfectly rigid, the critical load will be four times that for a similar column where there is no resistance to rotation (hinged at the ends).

Since the moment of inertia of a surface is its area multiplied by the square of a length called the radius of gyration, the above formula may be rearranged as follows. Using the Euler formula for hinged ends, and substituting A·r2 for I, the following formula results.

where is the allowable stress of the column, and is the slenderness ratio.

Since structural columns are commonly of intermediate length, and it is impossible to obtain an ideal column, the Euler formula on its own has little practical application for ordinary design. Issues that cause deviation from the pure Euler strut behaviour include imperfections in geometry in combination with plasticity/non-linear stress strain behaviour of the column's material. Consequently, a number of empirical column formulae have been developed to agree with test data, all of which embody the slenderness ratio. For design, appropriate safety factors are introduced into these formulae. One such formula is the Perry Robertson formula which estimates of the critical buckling load based on an initial (small) curvature. The Rankine Gordon formula is also based on experimental results and suggests that a strut will buckle at a load Fmax given by:

where Fe is the Euler maximum load and Fc is the maximum compressive load. This formula typically produces a conservative estimate of Fmax.

Read more about this topic:  Buckling

Famous quotes containing the word columns:

    A few more days, and this essay will follow the Defensio Populi to the dust and silence of the upper shelf.... For a month or two it will occupy a few minutes of chat in every drawing-room, and a few columns in every magazine; and it will then ... be withdrawn, to make room for the forthcoming novelties.
    Thomas Babington Macaulay (1800–1859)

    When I heard the learn’d astronomer,
    When the proofs, the figures, were ranged in columns before me,
    Walt Whitman (1819–1892)

    Rage is the only quality which has kept me, or anybody I have ever studied, writing columns for newspapers.
    Jimmy Breslin (b. 1929)