Standard Levels
A number of standard schemes have evolved which are referred to as levels. There were five RAID levels originally conceived, but many more variations have evolved, notably several nested levels and many non-standard levels (mostly proprietary). RAID levels and their associated data formats are standardised by the Storage Networking Industry Association (SNIA) in the Common RAID Disk Drive Format (DDF) standard.
Following is a brief textual summary of the most commonly used RAID levels.
-
- RAID 0 (block-level striping without parity or mirroring) has no (or zero) redundancy. It provides improved performance and additional storage but no fault tolerance. Hence simple stripe sets are normally referred to as RAID 0. Any drive failure destroys the array, and the likelihood of failure increases with more drives in the array (at a minimum, potential for catastrophic data loss is double that of isolated drives without RAID). A single drive failure destroys the entire array because when data is written to a RAID 0 volume, the data is broken into fragments called blocks. The number of blocks is dictated by the stripe size, which is a configuration parameter of the array. The blocks are written to their respective drives simultaneously on the same sector. This allows smaller sections of the entire chunk of data to be read off each drive in parallel, increasing bandwidth. RAID 0 does not implement error checking, so any error is uncorrectable. More drives in the array means higher bandwidth, but greater risk of data loss.
-
- In RAID 1 (mirroring without parity or striping), data is written identically to two drives, thereby producing a "mirrored set"; the read request is serviced by either of the two drives containing the requested data, whichever one involves least seek time plus rotational latency. Similarly, a write request updates the strips of both drives. The write performance depends on the slower of the two writes (i.e., the one that involves larger seek time and rotational latency); at least two drives are required to constitute such an array. While more constituent drives may be employed, many implementations deal with a maximum of only two; of course, it might be possible to use such a limited level 1 RAID itself as a constituent of a level 1 RAID, effectively masking the limitation. The array continues to operate as long as at least one drive is functioning. With appropriate operating system support, there can be increased read performance, and only a minimal write performance reduction; implementing RAID 1 with a separate controller for each drive in order to perform simultaneous reads (and writes) is sometimes called "multiplexing" (or "duplexing" when there are only two drives).
-
- In RAID 10 (mirroring and striping), data is written in stripes across the primary disks and then mirrored to the secondary disks. A typical RAID 10 configuration consists of four drives. Two for striping and two for mirroring. A RAID 10 configuration takes the best concepts of RAID 0 and RAID 1 and combines them to provide better performance along with the reliability of parity without actually having parity as with RAID 5 and RAID 6. RAID 10 is often referred to as RAID 1+0 (mirrored+striped).
-
- In RAID 2 (bit-level striping with dedicated Hamming-code parity), all disk spindle rotation is synchronized, and data is striped such that each sequential bit is on a different drive. Hamming-code parity is calculated across corresponding bits and stored on at least one parity drive.
-
- In RAID 3 (byte-level striping with dedicated parity), all disk spindle rotation is synchronized, and data is striped so each sequential byte is on a different drive. Parity is calculated across corresponding bytes and stored on a dedicated parity drive.
-
- RAID 4 (block-level striping with dedicated parity) is identical to RAID 5 (see below), but confines all parity data to a single drive. In this setup, files may be distributed between multiple drives. Each drive operates independently, allowing I/O requests to be performed in parallel. However, the use of a dedicated parity drive could create a performance bottleneck; because the parity data must be written to a single, dedicated parity drive for each block of non-parity data, the overall write performance may depend a great deal on the performance of this parity drive.
-
- RAID 5 (block-level striping with distributed parity) distributes parity along with the data and requires all drives but one to be present to operate; the array is not destroyed by a single drive failure. Upon drive failure, any subsequent reads can be calculated from the distributed parity such that the drive failure is masked from the end user. However, a single drive failure results in reduced performance of the entire array until the failed drive has been replaced and the associated data rebuilt. Additionally, there is the potentially disastrous RAID 5 write hole. RAID 5 requires at least three disks.
-
- RAID 6 (block-level striping with double distributed parity) provides fault tolerance of two drive failures; the array continues to operate with up to two failed drives. This makes larger RAID groups more practical, especially for high-availability systems. This becomes increasingly important as large-capacity drives lengthen the time needed to recover from the failure of a single drive. Single-parity RAID levels are as vulnerable to data loss as a RAID 0 array until the failed drive is replaced and its data rebuilt; the larger the drive, the longer the rebuild takes. Double parity gives additional time to rebuild the array without the data being at risk if a single additional drive fails before the rebuild is complete. Like RAID 5, a single drive failure results in reduced performance of the entire array until the failed drive has been replaced and the associated data rebuilt.
The following table provides an overview of the most important parameters of standard RAID levels. In each case:
- Array space efficiency is given as an expression in terms of the number of drives, ; this expression designates a value between 0 and 1, representing the fraction of the sum of the drives' capacities that is available for use. For example, if three drives are arranged in RAID 3, this gives an array space efficiency of (approximately 66%); thus, if each drive in this example has a capacity of 250 GB, then the array has a total capacity of 750 GB but the capacity that is usable for data storage is only 500 GB.
- Array failure rate is given as an expression in terms of the number of drives, and the drive failure rate, (which is assumed to be identical and independent for each drive). For example, if each of three drives has a failure rate of 5% over the next 3 years, and these drives are arranged in RAID 3, then this gives an array failure rate of over the next 3 years.
Level | Description | Minimum # of drives** | Space Efficiency | Fault Tolerance | Array Failure Rate*** | Read Benefit | Write Benefit | Image |
---|---|---|---|---|---|---|---|---|
RAID 0 | Block-level striping without parity or mirroring. | 2 | 1 | 0 (none) | 1−(1−r)n | nX | nX | |
RAID 1 | Mirroring without parity or striping. | 2 | 1/n | n−1 drives | rn | nX | 1X | |
RAID 2 | Bit-level striping with dedicated Hamming-code parity. | 3 | 1 − 1/n ⋅ log2(n-1) | RAID 2 can recover from 1 drive failure or repair corrupt data or parity when a corrupted bit's corresponding data and parity are good. | variable | variable | variable | |
RAID 3 | Byte-level striping with dedicated parity. | 3 | 1 − 1/n | 1 drive | n(n−1)r2 | (n−1)X | (n−1)X* | |
RAID 4 | Block-level striping with dedicated parity. | 3 | 1 − 1/n | 1 drive | n(n−1)r2 | (n−1)X | (n−1)X* | |
RAID 5 | Block-level striping with distributed parity. | 3 | 1 − 1/n | 1 drive | n(n−1)r2 | (n−1)X* | (n−1)X* | |
RAID 6 | Block-level striping with double distributed parity. | 4 | 1 − 2/n | 2 drives | n(n-1)(n-2)r3 | (n−2)X* | (n−2)X* |
* Assumes hardware is fast enough to support; ** Assumes a nondegenerate minimum number of drives; *** Assumes independent, identical rate of failure amongst drives
Read more about this topic: RAID
Famous quotes containing the words standard and/or levels:
“There is a certain standard of grace and beauty which consists in a certain relation between our nature, such as it is, weak or strong, and the thing which pleases us. Whatever is formed according to this standard pleases us, be it house, song, discourse, verse, prose, woman, birds, rivers, trees, room, dress, and so on. Whatever is not made according to this standard displeases those who have good taste.”